DR-15 series product dimension diagram | ||||
DR-15 | ||||
DR-15 series product parameter table | ||||
model performance |
DR-15-5 | DR-15-12 | DR-15-15 | DR-15-24 |
DC Voltage | 5V | 12V | 15V | 24V |
Rated current | 3A | 1.25A | 1A | 0.63A |
Current range | 0~3A | 0~1.25A | 0~1A | 0~0.63A |
rated power | 15W | 15W | 15W | 15.2W |
Ripples and Noise (Note 2) | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p |
Voltage adjustment range | 4.75~5.5V | 10.8~13.2V | 13.5~16.5V | 21.6~26.4V |
Voltage accuracy (Note 3) | ±2.0% | ±1.0% | ±1.0% | ±1.0% |
Line Regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Load Regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Start and rise time | 1000ms,50ms/230VAC 1000ms,50ms/150VAC(At full load) | |||
HOLD | 70ms/230VAC 16ms/115VAC(At full load) | |||
Voltage range | 85-264VAC或120~370VDC | |||
Frequency range | 47~63Hz | |||
efficiency | 77% | 84% | 83.50% | 85% |
Input Current | 0.88A/115VAC 0.48A/230VAC | |||
Impulse current | cold start:35A/115VAC 65A/230VAC | |||
Overload (Note 5) | 105%~160% of rated output power | |||
Protection mode: Constant current limit, automatically restored after removing abnormal load conditions | ||||
Overvoltage | 5.75~6.75V | 13.8~16.2V | 17.25~20.25V | 27.6~32.4V |
Protection mode: Turn off output voltage, diode clamp | ||||
Working humidity | 20~90% RH, non condensing | |||
temperature coefficient | ±0.03%/℃(0~50℃) | |||
Vibration | 10~500Hz, 2G 10 minutes/cycle, 60 minutes each for X, Y, and Z axes; Installation; Compliant with IEC60068-2-6 | |||
Safety regulations | UL60950-1, TUV EN60950-1 certified, designed according to EN50178 | |||
pressurization | I/P-O/P:3KVAC | |||
Insulation impedance | I/P-O/P:100M Ohms/ 500VDC/ 25℃/70% RH | |||
size | 25*93*56mm (W*H*D) | |||
package | 0.1Kg;140pcs/15Kg/0.92CUFT |
Dimensions of DR-45W Rail Series Products | ||||||||||||
DR-45W | ||||||||||||
Parameter Table for DR-30, 45W and 60 Rail Series Products | ||||||||||||
model | DR-30 | DR-45 | DR-60 | |||||||||
DC Voltage | 5V | 12V | 15V | 24V | 5V | 12V | 15V | 24V | 5V | 12V | 15V | 24V |
Rated current | 5A | 2.5A | 2A | 1.25A | 6A | 3.75A | 3A | 1.8A | 6.5A | 5A | 4A | 2.5A |
rated power | 25W | 30W | 30W | 36W | 30W | 45W | 43W | 48W | 32.5W | 60W | 60W | 60W |
Load Regulation | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Working current | <0.8A 110VAC <0.4A 220VAC | <1A 110VAC <0.5A 220VAC | <1.2A 110VAC <0.8A 220VAC | |||||||||
voltage | 5V | 12V | 15V | 24V | ||||||||
Ripple and noise (maximum) Note 2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | ||||||||
Voltage adjustment range | 4.75~5.5V | 10.8~13.2V | 13.5~16.5V | 21.6~26.4V | ||||||||
Voltage accuracy note 3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ||||||||
Line Regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||||||
Load Regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||||||
Start and rise time | 1000ms,50ms/230VAC 1000ms,50ms/150VAC(At full load) | |||||||||||
HOLD | 70ms/230VAC 16ms/115VAC(At full load) | |||||||||||
Voltage range | 85-264VAC or 120-370VDC | |||||||||||
Frequency range | 47~63Hz | |||||||||||
efficiency | 77% | 84% | 83.50% | 85% | ||||||||
Input Current | 0.88A/115VAC 0.48A/230VAC | |||||||||||
Impulse current | cold start:35A/115VAC 65A/230VAC | |||||||||||
Overload (Note 5) | 105%~160% of rated output power | |||||||||||
Protection mode: Constant current limit, automatically restored after removing abnormal load conditions | ||||||||||||
Overvoltage | 5.75~6.75V | 13.8~16.2V | 17.25~20.25V | 27.6~32.4V | ||||||||
Protection mode: Turn off output voltage, diode clamp | ||||||||||||
Working humidity | 20~90% RH, non condensing | |||||||||||
temperature coefficient | ±0.03%/℃(0~50℃) | |||||||||||
Vibration | 10~500Hz, 2G 10 minutes/cycle, 60 minutes each for X, Y, and Z axes; Installation; | |||||||||||
pressurization | I/P-O/P:3KVAC | |||||||||||
Insulation impedance | I/P-O/P:100M Ohms/ 500VDC/ 25℃/70% RH | |||||||||||
size | 78*93*56mm (W*H*D) |
DR-75 series product dimension diagram | |||
DR-75 | |||
DR-75 series product parameter table | |||
model performance |
DR-75-12 | DR-75-24 | DR-75-48 |
DC Voltage | 12V | 24V | 48V |
Rated current | 6.3A | 3.2A | 1.6A |
Current range | 0~6.3A | 0~3.2A | 0~1.6A |
rated power | 75.6W | 76.8W | 76.8W |
Ripples and Noise (Note 2) | 100mVp-p | 150mVp-p | 240mVp-p |
Voltage adjustment range | 10.8~13.2V | 21.6~26.4V | 43.2~52.8V |
Voltage accuracy (Note 3) | ±1.0% | ±1.0% | ±1.0% |
Adjustment rate of incoming line (Note 4) | ±0.5% | ±0.5% | ±0.5% |
Load adjustment rate (Note 5) | ±1.0% | ±1.0% | ±1.0% |
Start and rise time | 1000ms,50ms/230VAC 1000ms,50ms/150VAC(At full load) | ||
HOLD | 70ms/230VAC 16ms/115VAC(At full load) | ||
Input Voltage | 85-264VAC或120~370VDC | ||
Frequency range | 47~63Hz | ||
efficiency | 76% | 80% | 81.00% |
Input Current | 0.88A/115VAC 0.48A/230VAC | ||
Impulse current | cold start:35A/115VAC 65A/230VAC | ||
Overload (Note 5) | 105%~160% of rated output power | ||
Protection mode: Constant current limit, automatically restored after removing abnormal load conditions | |||
Overvoltage protection | 13.8~16.2V | 27.6~32.4V | 58~62V |
Protection mode: Turn off output voltage, diode clamp | |||
Working humidity | 20~90% RH, non condensing | ||
Storage temperature and humidity | ±0.03%/℃(0~50℃) | ||
temperature coefficient | 10~500Hz, 2G 10 minutes/cycle, 60 minutes each for X, Y, and Z axes; Installation; Compliant with IEC60068-2-6 | ||
Vibration | UL60950-1, TUV EN60950-1 certified, designed according to EN50178 | ||
pressurization | I/P-O/P:3KVAC | ||
Insulation impedance | I/P-O/P:100M Ohms/ 500VDC/ 25℃/70% RH | ||
size | ≥1172.3Khrs MIL-HDBK-217F (25℃) | ||
package | 55.5*125.2*100mm (W*H*D) |
DR-120 series product dimension diagram | |||
DR-120 | |||
DR-120 series product parameter table | |||
model performance |
DR-120-12 | DR-120-24 | DR-120-48 |
DC Voltage | 12V | 24V | 48V |
Rated current | 10A | 5A | 2.5A |
Current range | 0~10A | 0~5A | 0~2.5A |
rated power | 120W | 120W | 120W |
Ripples and Noise (Note 2) | 80mVp-p | 80mVp-p | 100mVp-p |
Voltage adjustment range | 10.8~13.2V | 21.6~26.4V | 43.2~52.8V |
Voltage accuracy (Note 3) | ±1.0% | ±1.0% | ±1.0% |
Adjustment rate of incoming line (Note 4) | ±0.5% | ±0.5% | ±0.5% |
Load adjustment rate (Note 5) | ±1.0% | ±1.0% | ±1.0% |
Start and rise time | 1000ms,50ms/230VAC 1000ms,50ms/150VAC(At full load) | ||
HOLD | 70ms/230VAC 16ms/115VAC(At full load) | ||
Input Voltage | 88-264VAC or 248~370VDC | ||
Frequency range | 47~63Hz | ||
efficiency | 80% | 84% | 85.00% |
Input Current | 3.3A/115 2A/230V | ||
Impulse current | cold start:35A/115VAC 65A/230VAC | ||
Overload (Note 5) | 105%~160% of rated output power | ||
Protection mode: Constant current limit, automatically restored after removing abnormal load conditions | |||
Overvoltage protection | 13.8~16.2V | 27.6~32.4V | 58~62V |
Protection mode: Turn off output voltage, diode clamp | |||
Working humidity | 20~90% RH, non condensing | ||
temperature coefficient | ±0.03%/℃(0~50℃) | ||
Vibration | 10~500Hz, 2G 10 minutes/cycle, 60 minutes each for X, Y, and Z axes; Installation; | ||
pressurization | I/P-O/P:3KVAC | ||
Insulation impedance | I/P-O/P:100M Ohms/ 500VDC/ 25℃/70% RH | ||
size | 65*125.2*100mm (W*H*D) | ||
package | 0.8Kg;140pcs/15Kg/0.92CUFT |
PHLTD rail switch power supply has excellent stability and efficiency. It adopts high-efficiency conversion technology to ensure that the power supply can stably output the required voltage within a wide input voltage range, meeting the application requirements in various complex environments. Meanwhile, its high-efficiency design can significantly reduce energy consumption, reduce heat generation, and extend the service life of the equipment.