PHLTD DR Rail Series Switching Power Supply

PHLTD DR Rail Series Switching Power Supply DR-15/60/75/120W DC Voltage 5V 12V 15V 24V

Short circuit, overload protection, small size, light weight

Categories: ,

PHLTD Rail Switch Power Supply DR Series Wiring Diagram 105%~160% of Overload Rated Output Power Frequency Range 47~63Hz

DR-15 series product dimension diagram
DR-15

PHLTD DR Rail Series Switching Power Supply 15W Size 25x93x56mm Voltage Range 85-264VAC or 120-370VDC

DR-15 series product parameter table
             model
performance
DR-15-5 DR-15-12 DR-15-15 DR-15-24
DC Voltage 5V 12V 15V 24V
Rated current 3A 1.25A 1A 0.63A
Current range 0~3A 0~1.25A 0~1A 0~0.63A
rated power 15W 15W 15W 15.2W
Ripples and Noise (Note 2) 80mVp-p 120mVp-p 120mVp-p 150mVp-p
Voltage adjustment range 4.75~5.5V 10.8~13.2V 13.5~16.5V 21.6~26.4V
Voltage accuracy (Note 3) ±2.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±1.0% ±1.0% ±1.0% ±1.0%
Load Regulation ±1.0% ±1.0% ±1.0% ±1.0%
Start and rise time 1000ms,50ms/230VAC   1000ms,50ms/150VAC(At full load)
HOLD 70ms/230VAC   16ms/115VAC(At full load)
Voltage range 85-264VAC或120~370VDC
Frequency range 47~63Hz
efficiency 77% 84% 83.50% 85%
Input Current 0.88A/115VAC    0.48A/230VAC
Impulse current cold start:35A/115VAC   65A/230VAC
Overload (Note 5) 105%~160% of rated output power
Protection mode: Constant current limit, automatically restored after removing abnormal load conditions
Overvoltage 5.75~6.75V 13.8~16.2V 17.25~20.25V 27.6~32.4V
Protection mode: Turn off output voltage, diode clamp
Working humidity 20~90% RH, non condensing
temperature coefficient ±0.03%/℃(0~50℃)
Vibration 10~500Hz, 2G 10 minutes/cycle, 60 minutes each for X, Y, and Z axes; Installation; Compliant with IEC60068-2-6
Safety regulations UL60950-1, TUV EN60950-1 certified, designed according to EN50178
pressurization I/P-O/P:3KVAC
Insulation impedance I/P-O/P:100M Ohms/ 500VDC/ 25℃/70% RH
size 25*93*56mm (W*H*D)
package 0.1Kg;140pcs/15Kg/0.92CUFT
Dimensions of DR-45W Rail Series Products
DR-45W

PHLTD DR Rail Series Switching Power Supply 30、45、60W Size 78x93x56mm Voltage Range 85-264VAC or 120-370VDC

Parameter Table for DR-30, 45W and 60 Rail Series Products
model DR-30 DR-45 DR-60
DC Voltage 5V 12V 15V 24V 5V 12V 15V 24V 5V 12V 15V 24V
Rated current 5A 2.5A 2A 1.25A 6A 3.75A 3A 1.8A 6.5A 5A 4A 2.5A
rated power 25W 30W 30W 36W 30W 45W 43W 48W 32.5W 60W 60W 60W
Load Regulation ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1%
Working current <0.8A 110VAC   <0.4A 220VAC <1A 110VAC   <0.5A 220VAC <1.2A 110VAC   <0.8A 220VAC
voltage 5V 12V 15V 24V
Ripple and noise (maximum) Note 2 80mVp-p 120mVp-p 120mVp-p 150mVp-p
Voltage adjustment range 4.75~5.5V 10.8~13.2V 13.5~16.5V 21.6~26.4V
Voltage accuracy note 3 ±2.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±1.0% ±1.0% ±1.0% ±1.0%
Load Regulation ±1.0% ±1.0% ±1.0% ±1.0%
Start and rise time 1000ms,50ms/230VAC   1000ms,50ms/150VAC(At full load)
HOLD 70ms/230VAC   16ms/115VAC(At full load)
Voltage range 85-264VAC or 120-370VDC
Frequency range 47~63Hz
efficiency 77% 84% 83.50% 85%
Input Current 0.88A/115VAC    0.48A/230VAC
Impulse current cold start:35A/115VAC   65A/230VAC
Overload (Note 5) 105%~160% of rated output power
Protection mode: Constant current limit, automatically restored after removing abnormal load conditions
Overvoltage 5.75~6.75V 13.8~16.2V 17.25~20.25V 27.6~32.4V
Protection mode: Turn off output voltage, diode clamp
Working humidity 20~90% RH, non condensing
temperature coefficient ±0.03%/℃(0~50℃)
Vibration 10~500Hz, 2G 10 minutes/cycle, 60 minutes each for X, Y, and Z axes; Installation;
pressurization I/P-O/P:3KVAC
Insulation impedance I/P-O/P:100M Ohms/ 500VDC/ 25℃/70% RH
size 78*93*56mm (W*H*D)
DR-75 series product dimension diagram
DR-75

DR-75 series product parameter table
             model
performance
DR-75-12 DR-75-24 DR-75-48
DC Voltage 12V 24V 48V
Rated current 6.3A 3.2A 1.6A
Current range 0~6.3A 0~3.2A 0~1.6A
rated power 75.6W 76.8W 76.8W
Ripples and Noise (Note 2) 100mVp-p 150mVp-p 240mVp-p
Voltage adjustment range 10.8~13.2V 21.6~26.4V 43.2~52.8V
Voltage accuracy (Note 3) ±1.0% ±1.0% ±1.0%
Adjustment rate of incoming line (Note 4) ±0.5% ±0.5% ±0.5%
Load adjustment rate (Note 5) ±1.0% ±1.0% ±1.0%
Start and rise time 1000ms,50ms/230VAC   1000ms,50ms/150VAC(At full load)
HOLD 70ms/230VAC   16ms/115VAC(At full load)
Input Voltage 85-264VAC或120~370VDC
Frequency range 47~63Hz
efficiency 76% 80% 81.00%
Input Current 0.88A/115VAC    0.48A/230VAC
Impulse current cold start:35A/115VAC   65A/230VAC
Overload (Note 5) 105%~160% of rated output power
Protection mode: Constant current limit, automatically restored after removing abnormal load conditions
Overvoltage protection 13.8~16.2V 27.6~32.4V 58~62V
Protection mode: Turn off output voltage, diode clamp
Working humidity 20~90% RH, non condensing
Storage temperature and humidity ±0.03%/℃(0~50℃)
temperature coefficient 10~500Hz, 2G 10 minutes/cycle, 60 minutes each for X, Y, and Z axes; Installation; Compliant with IEC60068-2-6
Vibration UL60950-1, TUV EN60950-1 certified, designed according to EN50178
pressurization I/P-O/P:3KVAC
Insulation impedance I/P-O/P:100M Ohms/ 500VDC/ 25℃/70% RH
size ≥1172.3Khrs     MIL-HDBK-217F (25℃)
package 55.5*125.2*100mm (W*H*D)
DR-120 series product dimension diagram
DR-120

PHLTD DR Rail Series Switching Power Supply 120W Size 65x125.2x100mm Voltage Range 88-264VAC or 120-370VDC

DR-120 series product parameter table
             model
performance
DR-120-12 DR-120-24 DR-120-48
DC Voltage 12V 24V 48V
Rated current 10A 5A 2.5A
Current range 0~10A 0~5A 0~2.5A
rated power 120W 120W 120W
Ripples and Noise (Note 2) 80mVp-p 80mVp-p 100mVp-p
Voltage adjustment range 10.8~13.2V 21.6~26.4V 43.2~52.8V
Voltage accuracy (Note 3) ±1.0% ±1.0% ±1.0%
Adjustment rate of incoming line (Note 4) ±0.5% ±0.5% ±0.5%
Load adjustment rate (Note 5) ±1.0% ±1.0% ±1.0%
Start and rise time 1000ms,50ms/230VAC   1000ms,50ms/150VAC(At full load)
HOLD 70ms/230VAC   16ms/115VAC(At full load)
Input Voltage 88-264VAC or 248~370VDC
Frequency range 47~63Hz
efficiency 80% 84% 85.00%
Input Current 3.3A/115 2A/230V
Impulse current cold start:35A/115VAC   65A/230VAC
Overload (Note 5) 105%~160% of rated output power
Protection mode: Constant current limit, automatically restored after removing abnormal load conditions
Overvoltage protection 13.8~16.2V 27.6~32.4V 58~62V
Protection mode: Turn off output voltage, diode clamp
Working humidity 20~90% RH, non condensing
temperature coefficient ±0.03%/℃(0~50℃)
Vibration 10~500Hz, 2G 10 minutes/cycle, 60 minutes each for X, Y, and Z axes; Installation;
pressurization I/P-O/P:3KVAC
Insulation impedance I/P-O/P:100M Ohms/ 500VDC/ 25℃/70% RH
size 65*125.2*100mm (W*H*D)
package 0.8Kg;140pcs/15Kg/0.92CUFT

PHLTD rail switch power supply has excellent stability and efficiency. It adopts high-efficiency conversion technology to ensure that the power supply can stably output the required voltage within a wide input voltage range, meeting the application requirements in various complex environments. Meanwhile, its high-efficiency design can significantly reduce energy consumption, reduce heat generation, and extend the service life of the equipment.

Reviews

There are no reviews yet.

Be the first to review “PHLTD DR Rail Series Switching Power Supply”

Your email address will not be published. Required fields are marked *

Shopping Cart