PHLTD FY waterproof series switch power supply

PHLTD brand FY series switching power supply FY with adjustable voltage ± 10%, output voltage 115-230VAC, size 236x135x65mm

PHLTD Brand FY Series Switching Power Supply FY Wiring Diagram Input Voltage 115-230VAC

FY-350 series product parameters
        model
performance
FY-350-5 FY-350-7.5 FY-350-12 FY-350-13.5 FY-350-15 FY-350-24 FY-350-27 FY-350-48
DC Voltage 5V 7.5V 12V 13.5V 15V 24V 27V 48V
output voltage tolerance ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
output current 50A 40A 29A 25.8A 23.2A 14.6A 13A 7.3A
Current range 0-50A 0-40A 0-29A 0-25.8A 0-23.2A 0-14.6A 0-13A 0-7.3A
Ripple and noise ① 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p
Stability of incoming lines ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load stability ±1% ±1% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
DC OUTPUT POWER 250W 300W 348W 348.3W 348W 350.4W 351W 350.4W
Efficiency (typical) ② 73% 76% 74% 79% 78% 81% 82% 83%
Adjustable range of DC voltage 4.5-5.6V 6-9V 10-13.2V 12-15V 13.5-18V 20-26.4V 26-32V 41-56V
Input Voltage 90~132VAC/80~264VAC Switch 47~63Hz;254~370VDC
Input Current 6.5A/115V 4A/230V
Impulse current 25A/115V 50A/230V
Leakage current <3.5mA240VAC
overload protection 105% ~150% Type;PUL singchiccup shutdown reset:Auto recovery
Overvoltage protection 5.75-6.75V 9.4-10.9V 9.4-10.9V 13.8-16.2V 15.5-18.2V 18-21V 33.7-34.4V 57.6-67V
temperature coefficient ±0.03%℃(0~50℃)
Start, rise

Hold time

200ms、50ms、20ms
Seismic resistance 10-500Hz; 2G 10min/cycle, duration of 60 minutes, for each axis
Pressure resistance Input output room: 1.5KVAC Input and housing: 1.5KVAC Output and housing: 0.5KVAC
Isolation resistor Output to output, input to housing, output to housing: 500VDC/100M Ω
Working temperature and humidity -10℃~+50℃;20%~90RH
Storage temperature and humidity -20℃~+85℃;10%-95RH
External dimensions 236*135*65mm 外壳912
weight 1.15kgs
safety standards DESIGN REFER TO U1950
EMC standards DESIGN REFER TO FCC PART15 CLASS A
FY-400 series product parameters
        model
performance
FY-400-9 FY-400-12 FY-400-13.5 FY-400-24 FY-400-48
DC Voltage 9V 12V 13.5V 24V 48V
output voltage tolerance ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
output current 43A 33A 29A 17A 8.3A
Current range 0-43A 0-33A 0-29A 0-17A 0-8.3A
Ripple and noise ① 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
Stability of incoming lines ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load stability ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
DC OUTPUT POWER 387W 396W 400W 400W 400W
Efficiency (typical) ② ±78% 83% 85% 85% 86%
Adjustable range of DC voltage ±10% ±10% ±10% ±10% ±10%
Input Voltage 170~264VDC
Input Current 5.6A/115V 2.8A/230V
Impulse current 40A/230V (冷态时)
Leakage current <3.5mA240VAC
overload protection 105%~135% Type: Cut off output reset: Automatic recovery
Overvoltage protection 5.75-6.75V 9.4-10.9V 9.4-10.9V 13.8-16.2V 15.5-18.2V 18-21V 33.7-34.4V 57.6-67V
temperature coefficient ±0.03%℃(0~50℃)
Start, rise

Hold time

150ms、50ms、20ms
Seismic resistance 10-500Hz; 2G 10min/cycle, duration of 60 minutes, for each axis
Pressure resistance Input output room: 1.5KVAC Input and housing: 1.5KVAC Output and housing: 0.5KVAC
Isolation resistor Output to output, input to housing, output to housing: 500VDC/100M Ω
Working temperature and humidity -10℃~+50℃;20%~90RH
Storage temperature and humidity -20℃~+85℃;10%-95RH
External dimensions 236*135*65mm 外壳912
weight 1.15kgs
safety standards Meets UL1950 requirements (does not apply for labeling)
EMC standards CLSPR22(EN55022),IEC1000-4.2.3.5.6.8.11 IEC1000-3-2